Warning: unlink(/home/globala/testing.globalautomationhk.com/storage/cache/cache.product.3f4cc11db45564b7dd6a2bd5b725eb66.1771524589): No such file or directory in /home/globala/testing.globalautomationhk.com/public_html/system/library/cache/file.php on line 79 IEC 60335-2-17 Spark Ignition Tester for Electric Blanket Flammability
IEC 60335-2-17 Spark Ignition Test Equipment for Electric Blanket Flame Retardancy
IEC 60335-2-17 Spark Ignition Test Equipment for Electric Blanket Flame Retardancy 

IEC 60335-2-17 Spark Ignition Test Equipment for Electric Blanket Flame Retardancy

  • Brand: global
  • Product Code: IEC 60335-2-17SparkIgnitionTest
  • Availability: 1000

Qty

IEC 60335-2-17 Spark Ignition Test Equipment for Electric Blanket Flame Retardancy

This spark ignition test device is designed in full compliance with IEC 60335-2-17, Clause 30.101, Figure 112 & Figure 113.

It is specifically developed to evaluate the flame retardancy and arc ignition resistance of flexible heating appliances used for personal or bedding heating.
The equipment verifies whether arc discharge from live parts can cause overheating, ignition, or combustion of the outer covering material under elevated temperature conditions.
  
Applicable Test Samples:
 
Electric blankets
Heating pads
Other flexible electric heating appliances intended for heating beds or the human body
 
 
Test Objective:
 
The test aims to determine whether the outer covering materials of flexible heating appliances can withstand electrical arcing without causing flame propagation or hazardous overheating, ensuring compliance with IEC safety requirements.
  Test Principle:
 The specimen is placed inside a temperature-controlled heating chamber and conditioned at 65°C ± 2°C for 3 hours.
After conditioning, the sample is mounted on a standard-compliant electrode support, with the electrode gap precisely set to 6.0 mm ± 0.1 mm.
A 10 kV sinusoidal rated voltage is applied across the electrodes. An adjustable non-inductive resistor is connected in series to maintain a short-circuit current of 1 mA, while ensuring the output voltage drop does not exceed 100 V.
The power is applied for 2 minutes, and the time taken for the spark to reach the inner edge of the template is recorded.
The final result is determined by calculating the average ignition time in accordance with IEC 60335-2-17 requirements.
 
System Configuration:
 
The spark ignition test system consists of:
High-voltage control unit (including 10 kV power supply)
Heating chamber (optional)
Standardized test bracket assembly
 Technical Parameters:
 

Component Description
Adjustable Platform 100 × 100 mm, stroke 0–100 mm, heat-insulating material
Lower Template Standard-made hardwood
Fixed Electrode Ø3 mm, 45° inverted cone tip, brass
Upper Template Standard-made hardwood or aluminum
Terminals Copper
Moving Electrode Ø3 mm cylindrical, flat top, brass
Electrode Gap Adjustable, 6.0 ± 0.1 mm
Base Thermal insulation material
Structure Stainless steel, insulation materials, and brass components

 
 Control Unit Specifications:
 

Item Specification
Output Voltage 0–15 kV
Output Current 0–2 mA
Short-Circuit Condition 1 mA with voltage drop ≤ 100 V
Test Time Setting 0–9999 s (presettable)
Time Recording 0–9999 s (spark to inner template edge)

Tags: Electric Blanket Tester, IEC 60335-2-17, Spark Ignition Equipment, Flame Retardancy Tester, Flammability Test, Safety Certification, Glow Wire Test, Appliance Testing, Fire Resistance, Laboratory Equipment, Heating Pad Tester, Textile Flammability, Fault Simulation, QA Testing, Home Appliance Safety.